EasyManua.ls Logo

Siemens S120 - Mounting

Siemens S120
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cabinet design and EMC for components, Blocksize format
10.8 Arrangement of components and equipment
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
441
10.8.2
Mounting
The components should be mounted on a conductive mounting surface to ensure low
impedance between the component and the mounting surface. Mounting plates with a
galvanized surface are suitable.
Figure 10-5 Mounting the CU310-2 onto a Power Module PM340 (frame size FSD)
Installation of PM340 Power Modules with base components
Many system components are designed as base components for PM340 Power Modules in
frame sizes FSA to FSE. In such cases, the base component is mounted on the mounting
surface and the PM340 Power Module in front of it, in order to save space.
Table 10- 18 Available base components
FSA
FSB
FSC
FSD
FSE
Line filter
x
-
-
-
-
Line reactor
x
x
x
x
x
Brake resistor
x
x
Motor reactor
x
x
x
x: base mounting possible
-: Not available as an external component (use a Power Module with an integrated line filter)