MOTION-CONNECT 500 power cables are mainly suitable for permanent routing. MOTION-
CONNECT 800PLUS power cables fulfill all of the high mechanical requirements for use in
tow chains. They are resistant to cutting oils.
Table 10- 11 Comparison of the MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS power cables
Power cable
MOTION-CONNECT 500
MOTION-CONNECT 800PLUS
Approvals
VDE
1)
cURus or UR/CSA
UR-CSA File No.
2)
in conformance with RoHS
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
Yes
UL758-CSA-C22.2-N.210.2-M90
Yes
Yes
Rated voltage V
0
/V in accordance with EN 50395
Supply cores
Signal cores
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
600 V / 1000 V
24 V (EN) 1000 V (UL/CSA)
Test voltage, rms
Supply cores
Signal cores
4 kV
2 kV
4 kV
2 kV
Operating temperature at the surface
Permanently installed
Moveable
-20 … 80 °C
0 … 60 °C
-50 … 80 °C
-20 … 60 °C
Tensile load, max.
Permanently installed
Moveable
50 N/mm
2
20 N/mm
2
50 N/mm
2
20 N/mm
2
Smallest bending radius
Permanently routed
Moving
3)
5 x D
max
approx. 18 x D
max
4 x D
max
approx. 8 x D
max
Torsional stress
30°/m absolute
30°/m absolute
Bending operations
100000 10 million
From 10 mm
2
: 3 million
Max. traversing speed
30 m/min
Up to 300 m/min
Max. acceleration
2 m/s
2
50 m/s
2
(3 m)
4)
insulation material
CFC/silicone-free CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
Oil resistance
EN 60811-2-1
(mineral oil only)
EN 60811-2-1
Protective jacket
PVC
DESINA color, orange RAL 2003
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color, orange, RAL 2003
Flame retardant
EN 60332-1-1 to 1-3
EN 60332-1-1 to 1-3
1)
The registration number is printed on the cable jacket.
2)
The file number is printed on the cable jacket.
3)
Detailed information on D
max
as well as the lowest permissible bending radius are provided in Catalog D31 in
Chapter "Connection system MOTION-CONNECT."
4)
Characteristic curves for accelerating can be found in Catalog D31 in Chapter "MOTION-CONNECT connection
system."