Loading...
Mains connection and line-side power components
3.7 Line filter
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
53
3.7.6
Mounting
The line filters are designed as base components. The line filter is retained on the mounting
surface and the Power Module is mounted on the line filter in a space-saving fashion. The
cables to the Power Modules are already connected at the line filter. The line filter is
connected to the line supply through terminals.
PM240-2 Power Module, frame size FSA
Line filter
Shield connection
Figure 3-8 Installation example: Power Module PM240-2 (frame size FSA) with screening kit and
line filter
Table 3- 2 Connecting the line filter for the PM240-2 on the mounting surface
Frame size
Fastening
Tightening torque
FSA
4 x M4 bolts
2.5 Nm
FSB
FSC
4 x M5 bolts
3 Nm