Cabinet design and EMC for components, Blocksize format
10.6 Connection Methods
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
431
Comparison of DRIVE-CLiQ signal cables
DRIVE-CLiQ signal cables are designed for various applications. The following table
provides an overview of the most important properties.
Table 10- 8 Properties of DRIVE-CLiQ signal cables
DRIVE-CLiQ
MOTION-CONNECT 500
DRIVE-CLiQ
MOTION-CONNECT 800PLUS
VDE
cURus or UR/CSA
UR-CSA File No.
1)
Yes
UL STYLE 2502/CSA-
N.210.2-M90
Yes
Yes
UL STYLE 2502/CSA-
N.210.2-M90
Yes
Yes
UL STYLE 2502/CSA-
N.210.2-M90
Yes
0
/V in
accordance with EN 50395
30 V 30 V 30 V
Operating temperature at the surface
Permanently installed
-20 … +80 °C
-20 … +80 °C
-20 … +80 °C
Permanently installed
45 N/mm
2
_
80 N/mm
2
2
50 N/mm
2
2
Permanently installed
50 mm
35 mm
35 mm
- 30°/m absolute 30°/m absolute
- 2 m/s
2
50 m/s
2
(3 m distance moved
2)
CFC/silicone-free CFC/silicone-free CFC/halogen/silicone-free
IEC 60754-1 / DIN VDE 0472-815
EN 60811-2-1 EN 60811-2-1
EN 60811-2-1
PVC
Gray RAL 7032
PVC
DESINA color green
PUR, HD22.10 S2
(VDE 0282, Part 10)
DESINA color green, RAL 6018
The file number is printed on the cable jacket.
Characteristic curves for accelerating can be found in Catalog "D31" in Chapter "MOTION-CONNECT connection