Mains connection and line-side power components
3.8 Line reactors
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
75
Table 3- 21 Technical data, Blocksize line reactors PM340, frame sizes FSD, FSE, and FSF
Line voltage 3-phase 380 VAC -10% to 480 VAC +10%
Suitable for
Power Module
6SL3210-
6SL3215-
1SE23-8xxx
1SE24-5xxx
1SE23-8UAx
1SE26-0xxx
1SE26-0UAx
1SE27-5xxx
1SE31-0xxx
1SE27-5UAx
1SE31-1xxx
1SE31-5xxx
1SE31-1UAx
1SE31-8xxx
1SE31-8UAx
Power loss
W 90 / 115 90 / 115 170 / 215 280 / 360 280 / 360
Line supply
connection
Screw-type
terminal
2
Screw-type
terminal
2
Screw-type
terminal
2
Flat connector
for M10 cable
Flat connector for
M10 cable lug
Load
connection
1U2, 1V2, 1W2
Cable
4 x 16 mm
2
Length approx.
Cable
4 x 16 mm
2
Length approx.
Cable
4 x 35 mm
2
Length approx.
Flat connector
for M10 cable
lug
Flat connector for
M10 cable lug
PE connection At the housing with
At the housing with
M8 screw
At the housing with
At the housing
At the housing
Degree of
protection
IP20 or IPXXB IP20 or IPXXB IP20 or IPXXB IP00 IP00
Table 3- 22 Technical data, Chassis line reactors
Suitable for
6SL3310- 1TE32-1AAx 1TE32-6AAx 1TE33-1AAx 1TE33-8AAx 1TE35-0AAx
Rated current of the
A 210 260 310 380 490
380 V 3 AC - 10 % … 480 V 3 AC + 10 % (-15 % < 1 min), 47 … 63 Hz
thmax
Line/load connection
1U1, 1V1, 1W1, 1U2,
M10
connecting
M10
connecting
M10
connecting
M12
connecting
M12
connecting