EasyManua.ls Logo

Siemens S120 - X131 Digital Inputs;Outputs and Analog Input

Siemens S120
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Control Units, Control Unit Adapters and operating components
7.3 Control Unit CU310-2 PN (PROFINET)
AC Drive
276 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
7.3.2.10
X131 digital inputs/outputs and analog input
Table 7- 11 X131 bidirectional digital inputs/outputs and analog input
Terminal
Designation
1)
Technical data
1
DI/DO 12
As input:
Voltage: -3 … 30 VDC
Current consumption, typical: 5 mA at 24 V
Level (incl. ripple)
High level: 15 … 30 V
Low signal level: -3 … 5 V (at ≤ 2 mA)
DI/DO 12, 13, 14, and 15 are rapid inputs
2)
Input delay (typ.):
For "0" → "1": 5 μs
For "1" → "0": 50 μs
As output:
Voltage: 24 VDC
Max. load current per output: 500 mA
Output delay (typ. / max.)
3)
:
For "0" → "1": 150 µs / 400 μs
For "1" → "0": 75 µs / 100 μs
Short-circuit, ground fault, overload proof
Automatic switch on again after overload trip
Switching frequency:
For ohmic load: Max. 100 Hz
For inductive load: Max. 0.5 Hz
For lamp load: Max. 10 Hz
Maximum lamp load: 5 W
2
DI/DO 13
3
GND
4
DI/DO 14
5 DI/DO 15
6
GND
Electronics ground
7
AI 0+
The analog input can be switched between a current or voltage input
using DIP switch S5.
Common-mode range
: ±12 V
As voltage input
: -10 … 10 V; R
i
> 100
Resolution: 12-bit + sign (with respect to the maximum range that
can be resolved -11 V ... 11 V)
As current input
: -20 ... 20 mA; Ri = 250 Ω
Resolution: 11-bit + sign (related to -22 … 22 mA)
Max. range that can be resolved: -44 … 44 mA
8 AI 0-
Type: Spring-loaded terminal 1 (Page 437)
Max. cross-section that can be connected: 1.5 mm
2
1)
DI/DO: bidirectional digital input/output; AI: Analog input
2)
The rapid inputs can be used as probe inputs or as inputs for the external zero mark.
3)
Data for: V
cc
= 24 V; load 48 Ω; high ("1") = 90% V
out
; low ("0") = 10% V
out
The maximum cable length that can be connected is 30 m.