EasyManua.ls Logo

Siemens S120 - Interface Description; Overview; X524 Electronics Power Supply

Siemens S120
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Supplementary system components and encoder system integration
8.2 Option module Safe Brake Relay
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
379
8.2.3
Interface description
8.2.3.1
Overview
Connection for the solenoid of the motor brake
Connection for the 24 VDC power supply
Connection for the pre-fabricated (CTRL) to the Power Module, Blocksize format
Figure 8-20 Interface description: Safe Brake Relay
8.2.3.2
X524 electronics power supply
Table 8- 22 X524 electronics power supply
Terminal
Function
Technical data
+
Electronics power supply
Voltage: 24 V (20.4 … 28.8 V)
Current consumption: max. 0.3 A (without motor
holding brake)
Maximum current via jumper in connector: 20 A
(15 A according to UL/CSA)
+
Electronics power supply
GND
Electronics ground
GND Electronics ground
Type: Screw-type terminal 2 (Page 437)
Max. cross-section that can be connected: 2.5 mm²
The maximum cable length that can be connected is 10 m.
Note
The two "+" and/or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.