Control Units, Control Unit Adapters and operating components
7.6 Control Unit Adapter CUA32
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
323
7.6
Control Unit Adapter CUA32
7.6.1
Description
The Control Unit Adapter CUA32 is used to connect a Power Module blocksize to an existing
DC/AC group with a higher-level control module, e.g. a CU320-2. Since the closed-loop
control is realized externally, for operation, a SINAMICS, SIMOTION, or SINUMERIK closed-
loop control is always required for several axes.
The CUA32 offers additional encoder interface (HTL / TTL / SSI).
The Control Unit Adapter CUA32 has the following interfaces (ports):
Table 7- 47 Interface overview of the CUA32
Type
Number
DRIVE-CLiQ interface
3
EP terminal/temperature sensor
1
Power Module Interface (PM-IF)
1
24 V electronics power supply
1
Encoder interface (HTL/TTL/SSI
(1)
)
1
1
Only SSI encoders without incremental tracks can be operated on the CUA32.