Power Modules
4.2 Blocksize Power Modules (PM240-2)
AC Drive
112 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Line voltage 3-phase 380 … 480 VAC ± 10%
Order number
without integrated line filter
with integrated line filter
6SL3210–
1PE11-8UL1
1PE11-8AL1
6SL3210–
1PE12-3UL1
1PE12-3AL1
6SL3210–
1PE13-2UL1
1PE13-2AL1
6SL3210–
1PE14-3UL1
1PE14-3AL1
3)
Without line filter
kg
1,4
1,4
1,4
1,4
Rated output of a typical standard induction motor at 400 V.
The input current depends on the motor load and line impedance. The input currents apply for a load with the type rating
(based on I
rated
) for a line impedance corresponding to u
k
= 1%.
Max. motor cable length 50 m (shielded) for PM240-2 Power Modules with integrated line filter to maintain the limit
values of EN 61800-3 Category C2.
Table 4- 12 Technical data of the PM240-2, FSA (400 V) (2/2)
Line voltage 3-phase 380 … 480 VAC ± 10%
Order number
without integrated line filter
with integrated line filter
6SL3210–
1PE16-1UL1
1PE16-1AL1
6SL3210–
1PE18-0UL1
1PE18-0AL1
6SL3211–
1PE18-0UL1
1PE18-0UL1
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
A
A
A
5,9
4,1
6,5
7,7
5,9
8,5
7,7
5,9
8,5
1)
based on I
n
based on I
H
kW
kW
2,2
1,5
3,0
2,2
3,0
2,2
kW 0,1 0,12 0,12
4)
3
for the Control Unit
A
1,0
1,0
1,0
2)
with/without integrated line reactor
A 7,7 10,1 10,1
Rated current
Short-circuit current rating
A
10
15
10
3NA3 803
3NA3 805