Supplementary system components and encoder system integration
8.1 Sensor Modules
AC Drive
354 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
X520 encoder system interface
Table 8- 8 X520: Encoder system interface
Ground for encoder power supply
Inverse incremental signal A
Ground (for internal shield)
Inverse incremental signal B
Ground (for internal shield)
Clock, EnDat interface, SSI clock
12 Clock*
Inverted clock, EnDat interface,
13 +Temp
1)
Motor temperature sensing KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130 / PTC
Sense input of encoder power supply
15 Data Data, EnDat interface,
SSI data
Ground sense input encoder power supply
Inverse reference signal R
Inverse absolute track signal C
Inverse absolute track signal D
23 Data* Inverse data, EnDat interface,
Ground (for internal shield)
25 -Temp
1)
Motor temperature sensing KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130 / PTC
Measuring current via temperature sensor connection: 2 mA
Accuracy of the temperature measurement:
- KTY: ±7°C (including evaluation)
- PTC: ±5℃ (including evaluation)