Supplementary system components and encoder system integration
8.1 Sensor Modules
AC Drive
362 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
X520 encoder system interface
Table 8- 13 X520: Encoder system interface
1 + Temp
1)
Motor temperature sensing KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130 / PTC
Encoder power supply
Sense input encoder power supply
Ground, encoder power supply
8 - Temp
1)
Motor temperature sensing KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130 / PTC
Inverse reference signal R
Inverse incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data
Measuring current via temperature sensor connection: 2 mA
1) Accuracy of temperature measurement:
- KTY: ±7°C (including evaluation)
- PTC: ±5℃ (including evaluation)
Damage to the encoder due to incorrect supply voltage
The encoder supply can be parameterized to 5 V or 24 V. The sensor may be destroyed if
you enter the wrong parameters.
• Select the appropriate supply voltage.
Damage to motor in the event of incorrectly connected KTY temperature sensor
A KTY temperature sensor connected with incorrect polarity cannot detect if the motor
overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
You can find information for parameterizing the KTY temperature sensor in the SINAMICS
S120 Function Manual (FH1) in Chapter "Monitoring and protective functions/thermal motor
monitoring".