Line Modules Booksize
3.2 Active Line Modules with internal air cooling
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
157
3.2.3.4 X200-X202 DRIVE-CLiQ interfaces
Table 3-3 DRIVE-CLiQ interface X200-X202
PIN Signal name Technical specifications
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 Reserved, do not use
5 Reserved, do not use
6 RXN Receive data -
7 Reserved, do not use
8 Reserved, do not use
A + (24 V) 24 V power supply
B M (0 V) Electronics ground
Blanking plate for DRIVE-CLiQ interface: Yamaichi, order no.: Y-ConAS-13