Cabinet Design and EMC Booksize
9.4 Arrangement of components and equipment
Booksize power units
512 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
9.4.3 Drive line-up
Due to the current carrying capacity of the DC link busbars and their function, the
components must be arranged according to the following rule. From left to right:
Line Module
Motor Modules in order of power from the highest power to the lowest power
DC link components (e.g. Braking Module, Control Supply Module, Capacitor Module)