Motor Modules Booksize Compact
5.7 Technical data
Booksize power units
394 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
5.7 5.7 Technical data
Table 5-9 Technical data for Single Motor Modules Booksize Compact (3 A to 18 A)
Motor Modules Booksize Compact 6SL3420– 1TE13-
0AAx
1TE15-
0AAx
1TE21–
0AAx
1TE21–
8AAx
Rated current A 3 5 9 18
Voltage
Infeed:
DC link voltage
Electronics power supply
V
DC
V
DC
510 – 720
24 (20.4 - 28.8)
Output voltage V
ACrms
0 - 0.717 x DC link voltage
Overvoltage trip threshold
Undervoltage trip threshold
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Current consumption of electronics at 24 V for
internal air cooling
A
DC
0.75 0.75 0.75 0.75
Current consumption of electronics at 24 V for
cold-plate cooling
A
DC
0.65 0.65 0.65 0.65
Total power loss for internal air cooling
(including electronics losses)
1)
W 68
at 8 kHz
98
at 8 kHz
98
at 4 kHz
178
at 4 kHz
Power loss distribution for cold plate (including
electronics losses)
internal
external
W
25.6
40
30.6
65
30.6
65
50.6
95
Rated output current (l
n
) A
ACrms
3 5 9 18
Base load current (I
base
) A 2.6 4.3 7.7 15.3
Intermittent duty current (l
s6
) 40 % A
ACrms
3.5 6 10 24
Peak current (l
max
) A
ACrms
9 15 27 54
DC link busbar current carrying capacity A
DC
100 100 100 100
24 V busbar current carrying capacity A
DC
20 20 20 20
Rated power
(with DC link voltage of 600 V
DC
and pulse
frequency of 4 kHz)
kW 1.6 2.7 4.8 9.7
Max. pulse frequency without derating kHz 8 8 4 4
Max. pulse frequency with derating kHz 16 16 16 16
Max. current motor brake A 2 2 2 2
Max. ambient temperature without derating °C 40 40 40 40
Max. ambient temperature with derating °C 55 55 55 55
DC link capacitance μF 110 110 110 235
Sound pressure level with internal air cooling dB(A) <60 <60 <60 <60
Cooling methods Internal air cooling/
cold-plate cooling
Cooling air requirement with internal air cooling m
3
/h 29.6 29.6 29.6 29.6
Max. permissible heat sink temperature cold plate °C 70 70 70 70
Weight kg 2.7 2.7 2.7 3.4
1)
For an overview, see the power loss tables in Chapter Cabinet design