Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
435
Motor-Side Power Components
7
7.1 7.1 Motor reactors
7.1.1 Description
Motor reactors reduce the voltage stress on the motor windings by reducing the voltage
gradients at the motor terminals that occur when motors are fed from drive converters. At the
same time, the capacitive re-charging currents that additionally load the output of the Power
Module when longer motor cables are used are simultaneously reduced.
Prerequisites
Ambient temperature 40 °C.
Pulse frequency f
max
=4 kHz.
Output frequency f
max
=120 kHz.
If the total shielded cable length in the drive line-up is more than 350 m, a Voltage
Clamping Module must be used.
If the total unshielded cable length in the drive line-up is more than 560 m, a Voltage
Clamping Module must be used.
Only valid for vector operating mode.
Supported in Starter from Version 2.4 up to 1 motor reactor.
Supported in Starter from Version 2.5 up to 3 motor reactors.