EasyManua.ls Logo

Siemens SINAMICS S120 - Technical Data

Siemens SINAMICS S120
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Modules Booksize
4.2 Motor Modules with internal air cooling
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
337
4.2.7 Technical data
Table 4-10 Technical data for Booksize Single Motor Modules (3 to 30 A)
Internal air cooling 6SL3120– 1TE13-
0AAx
1TE15-
0AAx
1TE21–
0AAx
1TE21–
8AAx
1TE23-
0AAx
Rated current A 3 5 9 18 30
Voltage
Infeed:
DC link voltage
Electronics power supply
V
DC
V
DC
510 – 720
24 (20.4 - 28.8)
Output voltage V
ACrms
0 - 0.717 x DC link voltage
Overvoltage trip threshold
Undervoltage trip threshold
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics current consumption at 24 V A
DC
0.85 0.85 0.85 0.85 0.9
Total power loss
(including electronic losses)
1)
W 50.4 75.4 100.4 185.4 311.6
Rated output current (l
n
) A
ACrms
3 5 9 18 30
Base load current (I
base
) A 2.6 4.3 7.7 15.3 25.5
Intermittent duty current (l
s6
) 40 % A
ACrms
3.5 6 10 24 40
Peak current (l
max
) A
ACrms
6 10 18 36 56
DC link busbar current carrying capacity A
DC
100 100 100 100 100
24 V busbar current carrying capacity A
DC
20 20 20 20 20
Rated power
(with DC link voltage of 600 V
DC
and pulse
frequency of 4 kHz)
kW 1.6 2.7 4.8 9.7 16
Max. pulse frequency without derating kHz 4 4 4 4 4
Max. pulse frequency with derating kHz 16 16 16 16 16
Max. ambient temperature without derating °C 40 40 40 40 40
Max. ambient temperature with derating °C 55 55 55 55 55
DC link capacitance μF 110 110 110 220 705
Sound pressure level dB(A) <60 <60 <60 <60 <60
Cooling type Internal
fan
Internal
fan
Internal
fan
Internal
fan
Internal
fan
Cooling air requirement m
3
/h 29.6 29.6 29.6 29.6 56
Weight kg 5 5 5 5 6.9
1)
For an overview, see the power loss tables in Chapter Cabinet design