EasyManua.ls Logo

Siemens SINAMICS S120 - Page 338

Siemens SINAMICS S120
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor Modules Booksize
4.2 Motor Modules with internal air cooling
Booksize power units
338 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Table 4-11 Technical data for Single Motor Modules booksize (45 to 200 A)
Internal air cooling 6SL3120– 1TE24-5AAx 1TE26-0AAx 1TE28-5AAx 1TE31-3AAx 1TE32-0AAx
Rated current A 45 60 85 132 200
Voltage
Infeed:
DC link voltage
Electronics power supply
V
DC
V
DC
510 – 720
24 (20.4 - 28.8)
Output voltage V
ACrms
0 - 0.717 x DC link voltage
Overvoltage trip threshold
Undervoltage trip threshold
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics current
consumption at 24 V
A
DC
1.2 1.2 1.5 1.5 1.5
Total power loss
(incl. electronic losses)
1)
W 458.8 618.8 786 1286 2086
Rated output current (l
n
) A
ACrms
45 60 85 132 200
Base load current (I
geund
) A 38 51 68 105 141
Intermittent duty current (l
s6
)
40 %
A
ACrms
60 80 110 150 230
Peak current (l
max
) A
ACrms
85 113 141 210 282
DC link busbar current
carrying capacity
A
DC
200 200 200 200 200
24 V busbar current carrying
capacity
A
DC
20 20 20 20 20
Rated power
(with DC link voltage of 600
V
DC
and clock cycle
frequency of 4 kHz)
kW 24 32 46 71 107
Max. pulse frequency
without derating
kHz 4 4 4 4 4
Max. pulse frequency with
derating
kHz 16 16 16 16 16
Max. ambient temperature
without derating
°C 40 40 40 40 40
Max. ambient temperature
with derating
°C 55 55 55 55 55
DC link capacitance μF 1175 1410 1880 2820 3995
Sound pressure level dB(A) <65 <65 <60 <73 <73
Cooling method (with fan) Internal fan Internal fan Internal fan Mounted fan Mounted fan
Cooling air requirement m
3
/h 112 112 160 520 520
Weight kg 9 9 15 21 21
1)
For an overview, see the power loss tables in Chapter Cabinet design

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals