Booksize DC Link Components   
6.3 Control Supply Module 
  Booksize power units 
424  Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6 
The Control Supply Module (CSM) is connected to the line supply (3-ph. 380 V AC –10 % up 
to 480 V +10 %) via the appropriate screw terminals (0.2 to 4 mm
2
). This connection should 
preferably be made without using an isolating device (e.g. contactor). 
The CSM is protected corresponding to the data provided in the Equipment Manual for 
Booksize power units. The CSM has an internal line filter (Class A for TN line supplies), and 
the pre-charging circuit for the DC link inside the unit is electrically isolated from the 24 V 
supply. 
 
 
Note 
When engineering the line supply of the CSM, it should be noted that the CSM may not be 
connected to the line supply after the line module is connected to the line supply. When 
charging, this prevents the DC link from being immediately loaded by the CSM. 
 
NOTICE 
 
If a selectively tripping AC/DC-sensitive residual-current circuit-breaker is used, the Control 
Supply Module must be connected downstream of this. 
 
6.3.3.3  Meaning of the LEDs on the Control Supply Module 
Table 6-8  Control Supply Module – description of the LEDs 
LED  Color  Status  Description, cause  Remedy 
-  off  Electronics power supply is missing or outside permissible 
tolerance range. 
– READY 
Green  Continuous  Component is ready to operate.  – 
-  off  Electronics power supply is missing or outside permissible 
tolerance range. 
– 
Orange  Continuous  DC link voltage within permissible tolerance range.  – 
DC LINK 
Red  Continuous  DC link voltage outside permissible tolerance range.  –