5.3.7 Meaning of the LEDs on the Motor Module
Table 5-5 Single Motor Module/Double Motor Module/Power Module - description of the LEDs
Status Description, cause Remedy
Ready (H200) DC link (H201)
OFF OFF Electronics power supply is missing or outside
permissible tolerance range.
OFF The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
Orange The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is present.
Green
Red The component is ready for operation and cyclic
DRIVE-CLiQ communication is taking place.
The DC link voltage is too high.
Check supply voltage
Orange Orange DRIVE-CLiQ communication is being established.
Red At least one fault is present in this component.
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Remedy and acknowledge
fault
Green/red
(0.5 Hz)
Firmware is being downloaded.
Green/red
(2 Hz)
- Firmware download is complete. Wait for POWER ON. Carry out a POWER ON
Green/orange
or
Red/orange
Component detection via LED is activated (p0124).
Note:
Both options depend on the LED status when
component recognition is activated via p0124 = 1.
DANGER
Hazardous DC link voltages may be present at any time regardless of the status of the "DC
link" LED.