EasyManua.ls Logo

Siemens SINAMICS S120 - Electrical Connection

Siemens SINAMICS S120
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
8.3 DC link adapter
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
477
8.3.6 Electrical connection
Required tools:
Hexagon-socket spanner (size 6)
Suitable tool for tube clips (e.g. flat-bladed screwdriver)
Table 8-16 Electrical connection of the DC link adapter for a 150 mm component
Route the cable through the tube clip and insert it into the
DC link adapter
Secure the cable
Secure the tube clip The cable is connected
Only shielded connection cables should be used.
The DC link adapter can be fitted on the right or left.