EasyManua.ls Logo

Siemens SINAMICS S120 - Page 476

Siemens SINAMICS S120
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories
8.3 DC link adapter
Booksize power units
476 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Table 8-14 Installing the DC link adapter for a 150 mm component
Unlock and open the protective cover Unscrew the screws.
Secure the adapter (1.8 Nm). The 24 V adapter is installed
and the protective cover is closed.
Note
By moving the adapter housing, the DC link adapter can be fitted on either the left-hand or
right-hand side of the module. This is possible with Active Line Modules as of 55 kW; see
overview below.
Table 8-15 Overview
Active Line Module Internal air cooling External air cooling
55 kW 6SL3130-7TE25-5AA2 6SL3131-7TE25-5AA0
(only with DC link busbars)
80 kW 6SL3130-7TE28-0AA1 6SL3131-7TE28-0AA0
(only with DC link busbars)
120 kW 6SL3130-7TE31-2AA1 6SL3131-7TE31-2AA0
(only with DC link busbars)