Accessories 
  8.5 DRIVE-CLiQ cabinet gland 
Booksize power units 
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6 
487 
8.5.5  Mounting 
0
1P
&DELQHWSDQHO
'5,9(&/L4FDELQHWJODQG
 
Figure 8-21  DRIVE-CLiQ cabinet gland 
Installation 
1.  Make an opening in the cabinet panel according to the Chapter "Dimension drawing" for 
the DRIVE-CLiQ cabinet gland. 
2.  Insert the components from the outer side of the cabinet through the opening in the 
cabinet. 
3.  Secure the DRIVE-CLiQ cabinet gland to the outer cabinet panel using two M3 screws 
and two nuts. In order to ensure good electromagnetic compatibility, a good electrical 
connection must be established between the DRIVE-CLiQ cabinet gland and the cabinet 
panel.