Motor Modules Booksize Compact
5.7 Technical data
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
395
Table 5-10 Technical data Double Motor Modules Booksize Compact (2 x 1.7 A to 2 x 5 A)
Double Motor Modules Booksize Compact 6SL3420- 2TE11-0Aax 2TE13-0Aax 2TE15-0Aax
Rated current A 2 x 1.7 2 x 3 2 x 5
Voltage
Infeed:
DC link voltage
Electronics power supply
V
DC
V
DC
510 – 720
24 (20.4 - 28.8)
Output voltage V
ACrms
0 - 0.717 x DC link voltage
Overvoltage tripping
Undervoltage tripping
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics current consumption at 24 V A
DC
1.0 1.0 1.0
Total power loss
(including electronics losses)
1)
at 8 kHz
W 114 134 194
Power loss distribution for cold plate (including
electronics losses)
internal
external
W
42
72
44
90
59
135
Rated current (I
n
) A 2 x 1.7 2 x 3 2 x 5
Base load current (I
base
) A 2 x 1.5 2 x 2.6 2 x 4.3
Intermittent duty current (l
S6
) 40 % A
ACrms
2 x 2 2 x 3.5 2 x 6
Peak current (l
max
) A
ACrms
2 x 5.1 2 x 9 2 x 15
DC link busbar current carrying capacity A 100 100 100
24 V busbar current carrying capacity A 20 20 20
Rated power (600 V, 8 kHz) kW 2 x 1 2 x 1.6 2 x 2.7
Max. pulse frequency without derating kHz 8 8 8
Max. pulse frequency with derating kHz 16 16 16
Max. current motor brake A 2 x 2 2 x 2 2 x 2
Max. ambient temperature without derating °C 40 40 40
Max. ambient temperature with derating °C 55 55 55
DC link capacitance μF 165 165 165
Sound pressure level dBA <60 <60 <60
Cooling methods Internal air cooling with installed fan
cold-plate cooling
Cooling air requirement m
3
/h 29.6 29.6 29.6
Max. permissible heat sink temperature cold plate °C 65 70 70
Weight kg 3.4 3.4 3.4
1)
For an overview, see the power loss tables in Chapter Cabinet design