EasyManua.ls Logo

Siemens SINAMICS S120 - Page 188

Siemens SINAMICS S120
570 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Line Modules Booksize
3.3 Active Line Modules with external air cooling
Booksize power units
188 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
0

,QWHUPHGLDWHSLHFH
$GDSWHUSODWHRU
PRXQWLQJSODWH
5HLQIRUFLQJEUDFNHW

;
;









$
%
E

$
E
Figure 3-22 Installation openings for the power unit with external air cooling, 300 mm
Table 3-20 Dimensions of the installation openings for the power unit with external air cooling
Component width W [mm] (inches) w1 [mm] (inches) w2 [mm] (inches)
50 mm 41.5 + 0.3 (1.63 + 0.012) 20.75 +0.15 (0.82 +0.006) 0
100 mm 89.5 + 0.3 (3.52 + 0.012) 19.75 +0.15 (0.78 + 0.006) 50 ± 0.15 (1.97 ± 0.006)
150 mm 133 + 0.3 (5.24 + 0.012) 16.5 +0.15 (0.65 + 0.006) 100 ± 0.15 (3.94 ± 0.006)
200 mm 173 + 0.3 (6.81 + 0.012) 11.5 +0.15 (0.45 + 0.006) 150 ± 0.15 (5.91 ± 0.006)
300 mm 278 + 0.3 (10.94 + 0.012) 14.0 ± 0.15 (0.55 ± 0.006) 250 + 0.15 (9.84 + 0.006)