Line Modules Booksize
3.4 Basic Line Modules with internal air cooling
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
225
Internal air cooling 6SL3130- 1TE22-0AA0 1TE24-0AA0 1TE31-0AA0
Maximum permissible DC link
capacitance
μF 20 000 20 000 50 000
Power factor
4)
cosϕ 0.98 0.98 0.98
Circuit-breaker type designation
UL489/CSA C22.2 No. 5-02
(status 07/2007 and later)
Rated current
Short-circuit current rating SCCR at
400 V
AC
Short-circuit current rating SCCR at
480 V
AC
Short-circuit current rating SCCR at
600 V
AC
A
kA
kA
kA
3RV1042-4MA10
80 ... 100
100
3VL2110-3KN30-
0AA0
100
100
25
3VL3125-3KN30-
0AA0
250
100
25
UL safety fuse type AJT Class J
Rated current
Short-circuit current rating SCCR at
600 V
AC
A
kA
AJT80
80
200
AJT100
100
200
AJT250
250
200
Safety fuses NH
Rated current
A
3NA3 822
63
3NA3 132
125
3NA3 144
250
Cooling method (internal air cooling) Internal fan Internal fan Internal fan
Sound pressure level dB(A) <60 dB <65 dB <65 dB
Cooling air requirement m
3
/h 56 112 180
Rated voltage for rated data 380 V 3 AC
Weight kg 6.8 11.3 15.8
1)
The specified values apply to 380 V
2)
Can also be operated on 200 ... 240 V 3 AC ±10 % networks with necessary parameterization and at lower power.
3)
For an overview, see power dissipation tables in Chapter Cabinet design
4)
Fundamental component only