Line Modules Booksize
3.8 Smart Line Modules (5 kW und 10 kW) with external air cooling
Booksize power units
314 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Derating as a function of the ambient temperature

>r&@


>@


 


3HUPLVVLEOHRXWSXWSRZHU
$PELHQWWHPSHUDWXUH
Figure 3-97 Derating as a function of the ambient temperature
Derating as a function of the installation altitude
 
>P@



>@





 

,QVWDOODWLRQDOWLWXGHDERYHVHDOHYHO
3HUPLVVLEOHRXWSXWFXUUHQW
Figure 3-98 Derating as a function of the installation altitude