Machine and Setting Data 802D
A.1 List of machine data
A-203
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
10880 MM_EXTERN_CNC_SYSTEM
– Def. of control system to be adapted POWER ON
N01, N12 – DWORD
Default – 1 1 3 2/2
10881 MM_EXTERN_GCODE_SYSTEM
– ISO_3 Mode: GCodeSystem POWER ON
N01, N12 – DWORD
Default – 0 0 2 2/2
10882 NC_USER_EXTERN_GCODES_TAB
– List of user–specific G commands, ext. language POWER ON
N12 – STRING
Default 60 – – 2/2
10884 EXTERN_FLOATINGPOINT_PROG
– Evaluation of progr. values without decimal point POWER ON
N12 – BOOLEAN
Default – TRUE – – 2/2
10886 EXTERN_INCREMENT_SYSTEM
– Increment system POWER ON
N12 – BOOLEAN
Default – FALSE – – 2/2
10888 EXTERN_DIGITS_TOOL_NO
– Number of digits for T number POWER ON
N12 – BYTE
Default – 2 0 8 2/2
10890 EXTERN_TOOLPROG_MODE
– Tool change program with ext. language POWER ON
N12 – DWORD
Default – 0 – – 2/2
11100 AUXFU_MAXNUM_GROUP_ASSIGN
– Number of auxiliary functions in AuxF groups POWER ON
N01, N07, N02 – DWORD
plus – 1 1 255 2/2
11160 ACCESS_EXEC_CST
– Right of execution for /_N_CST_DIR POWER ON
N01 – BYTE
Default – 7 – – 2/2
11161 ACCESS_EXEC_CMA
– Right of execution for /_N_CMA_DIR POWER ON
N01 – BYTE
Default – 7 – – 2/2
11162 ACCESS_EXEC_CUS
– Right of execution for /_N_CUS_DIR POWER ON
N01 – BYTE
Default – 7 – – 3/3
11165 ACCESS_WRITE_CST
– Right protection for /_N_CST_DIR POWER ON
N01 – DWORD
Default – –1 – – 2/2
11166 ACCESS_WRITE_CMA
– Right protection for directory /_N_CMA_DIR POWER ON
N01 – DWORD
Default – –1 – – 2/2