Start-upprocedures
4CheckagainthattheLEDonthefrontofthePhase
WatchRelay(K303)islit.
5
SwitchoffthemotorprotectingswitchS301bypressing
theoperatinghandledownwardstoOFFposition.
Checkthecontactoroperation
Procedure
Normally,inthispartofthetestprocedure,thetransducershaft
willbeinupperpositionwiththeupperlimitswitchactivated.
Thisoperationaltestofthehoist/lowercontactorswillnotrequire
the3-phasepowertobeappliedtothemotor.
Figure44MotorControlUnitwithS301,S302,K301,K302
andL2
Tomakesurethattheprocedureisfollowed,tickoffeachtask
afterithasbeendone.
1
LocatethemotorprotectingswitchS301,andcheck
thattheoperatinghandleispresseddowntoOFFposition.
2
CheckthattheLEDindicatorL2onthefrontofthe
24Vdcpowersupplyislit.
3
Setthehoist/lowerswitchS302toHOISTposition,and
checkthatthehoistingcontactorK301isn
o t activated.
Ifthecontactorwasactivated,presstheupperlimitswitch
S304upwards,andcheckthatthecontactorisdeactivated.
4
Setthehoist/lowerswitchS302totheLOWERposition
andcheckthattheloweringcontactorK302isactivated.
307531/C