EasyManua.ls Logo

Simrad SX90 - INSTALLATION REV C - Apply 3-Phase AC Power

Simrad SX90 - INSTALLATION REV C
246 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SimradSX90
Apply3-phaseACpower
Howtoapply3–phasepower
Tomakesurethattheprocedureisfollowed,tickoffeachtask
afterithasbeendone.
Figure41MotorControlUnitwithS301andE301
(CD015409K)
HOIST STOP
REMOTE LOWER
E301
S301
S302
1 LocatethemotorprotectingswitchS301intheMotor
ControlUnit,andcheckthattheoperatinghandleispressed
downtoOFFposition.
2
Checkthatthehoist/lowerswitchS302intheMotor
ControlUnitissetintheSTOPposition.
3
Re-insertthe3-phasemainsfusesforthehullunitin
theship’sfusebox.
4
Measurethethree-phasevoltageontheterminalsE301
intheMotorControlUnit.
Writedownthemeasuredvoltagehere:
Supplyvoltage:
5 Adjustthereleasecurrentonthemotorprotecting
switchS301accordingtothethree-phasevoltage:
230V ac:10A(maximum)
380/440Vac:6,5A