AppendixCSX90cabledetails
InterfaceUnitseriallines
TheInterfaceUnitprovidessevenseriallinecommunication
ports.TheseareavailableonterminalblocksTB1throughTB7,
andallareidentical.Forconnectiontotheperipheralunits,refer
totheapplicabledocumentationfortheunitinquestion.These
cablesarenotincludedwiththedelivery,andmustbeprovided
bytheinstallationshipyard.
Terminalboards
ATB4
BTB1,TB2andTB3
CTB5,TB6andTB7
Cablespecications
•Conductors:5x0.5mm²
•Screen:Overallbraided
•V oltage:60V
•Maximumdiameter:Denedbytheplugs