EasyManua.ls Logo

Simrad SX90 - INSTALLATION REV C - Cable Connections; Cable Terminations; Grounding

Simrad SX90 - INSTALLATION REV C
246 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SimradSX90
Grounding
Allmetalliccablecoverings(armour,metallicsheathingetc.)
mustbeelectricallyconnectedtothevessel’shullatbothends
exceptinthecaseofnalsub-circuitswheretheyshouldbe
connectedatthesupplyendonly.
Groundingconnectionsshouldbemadeusingaconductorwhich
hasacross-sectionalareaappropriateforthecurrentratingofthe
cable,orwithametalclampwhichgripsthemetalliccovering
ofthecableandisbondedtothehullofthevessel.Thesecable
coveringsmayalsobegroundedbymeansofglandsspecially
intendedforthispurposeanddesignedtoensureagoodground
connection.Theglandsusedmustbermlyattachedto,and
ingoodelectricalcontactwith,ametalstructuregroundedin
accordancewiththeserecommendations.
Electricalcontinuitymustbeensuredalongtheentirelength
ofallcablecoverings,particularlyatjointsandsplices.Inno
caseshouldtheshieldingofcablesbeusedastheonlymeans
ofgroundingcablesorunits.
Metalliccasings,pipesandconduitsmustbegrounded,andwhen
ttedwithjointsthesemustbemechanicallyandelectrically
groundedlocally.
Cableconnections
Allcableconnectionsareshownontheapplicablecableplan
andinterconnectiondiagrams.
Wherethecableplanshowscableconnectionsoutsidean
equipmentboxoutline,theconnectionsaretobemadetoaplug
orsocketwhichmatchestheplugorsocketonthatparticular
itemofequipment.
Wheretwocablesareconnectedinseriesviaajunctionboxor
terminalblock,thescreensofbothcablesmustbeconnected
togetherbutnotgrounded.
Cableterminations
Caremustbetakentoensurethatthecorrectterminations
areusedforallcableconductors,especiallythosethatare
tobeconnectedtoterminalblocks.Inthiscase,crimped
sleeve-terminationsmustbettedtopreventtheconductorcore
fromfrayingandmakingabadconnectionwiththeterminal
block.Itisalsooftheutmostimportancethatwherecrimped
terminationsareused,thecorrectsizeofcrimpandcrimpingtool
areused.Inaddition,eachcableconductormusthaveaminimum
of15cmslack(serviceloop)leftbeforeitsterminationistted.
216
307531/C

Table of Contents