Start-upprocedures
2Estimatetheapproximateoffsetangle(0to360degrees)
clockwisefromthe0degreestransducermarktothe0
degreesreferencestabilisationmark.
Theanglebetweeneachmountingboltcanbeusedas
anaid;
20boltsversion:18degreesbetweeneachbolt.
24boltsversion:15degreesbetweeneachbolt.
3Recordtheestimatedoffsetangle.Writeitdownhere:
Offsetangle(degrees):
Howtoenterthestabilisationoffsetangle
1OpentheSetupmenu.
2ClicktheTestbuttontoopentheSystemtestmenu.
3ClicktheInstallationMenubutton,andobservethemenu
thatappearsonthetopofthedisplay.
4SelectInstallation→Installation→Alignment.
5ObservethattheSonartransceivercongurationparameter
dialogueappearsatthebottomofthemenueld.
6ClicktheOffsetbutton.
7Entertheestimatedoffsetangle.
Deningownshipparameters
Inordertoachieveaccuratereadingsfromthesonarsystem,
certainvesselparametersmustbeentered.
Specifyshipdimensions
Togetthecorrectsizeofthevesselsymbolonthedisplay,the
lengthandwidthhavetobeadjustedinthefollowingmanner.
1OpentheSetupmenu.
2ClicktheTestbuttontoopentheSystemtestmenu.
3ClicktheInstallationMenubutton,andobservethemenu
thatappearsonthetopofthedisplay.
4SelectInstallation→Ownship→Shipdimensions.
5ObservethattheShipDimensionsparameterdialogue
appearsatthebottomofthemenueld.
6ClicktheShipLengthbutton,andentertheappropriatevalue.
7PresstheShipWidthbutton,andentertheappropriatevalue.
8ClickClosetonish.
Whenanewdisplaymodeisselected,thevesselsymbolonthe
sonarscreenwillchangetothedenedsize.