Note
Inordertoobtainoptimalsonarperformance,thetotalheight
ofthetrunkmustbeascloseaspossibletoitsstatedminimum
height.
Thetopangemustbeparalleltotheconstructionwaterlinein
boththefore-and-aftandathwartshipdirections.
Theinstallationtrunkmustbeweldedtoadoublingplatewhich
mustbeatleast1.5timesasthickasthesurroundingshellplating.
Thedoublingplate’snaldimensionsaretobegovernedbythe
approvedinstallationdrawingssuppliedbytheshipyard.The
trunkmustalsobestiffenedbyweldingknee-platestoitandthe
doublingplateinboththefore-and-aftandathwartshipdirections.
Sonartrunkprotection
Protectingtheblister
Asteelblistermustbettedforprotection.Theblistershown
isweldedtotheshellplatingandthenlledwithoiltoprevent
corrosion.Thismethodprovidesexcellentprotectionand
simpliesmaintenance.
Corrosionprotection
Assoonasallinstallation,weldingandgrindinghasbeen
performed,thetrunkandthesurroundingareashouldbeprimed
andpaintedusingaqualityprotectivecoating.