EasyManua.ls Logo

Simrad SX90 - INSTALLATION REV C - Source Level Test Results

Simrad SX90 - INSTALLATION REV C
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SimradSX90
Note
Donotremovethehydrophonefromthepositionusedforthe
sourcelevelmeasurements.Thisknownpositionshouldalso
beusedforthereceivingvoltageresponse(VR)measurements
inthenextsection.
Sourceleveltestresults
Thetwotablescreatedforthetestresultsareprovidedbelow.
Table7Measurementsresults
Measurements/calculations
ValueUnitExample
Measuredtimedelay
msec
5
r=1,5*t
meter
7,5
Distancefrom
hydrophone
totransducer
20logRdB17,5
U(p-p)
volt0,9
U(rms)=U(p-p)/2/√2
volt0,32
Hydrophone
voltagein
Omni
UHydr=20logU(rms)dB//1V
-9,9
U(p-p)
volt1,8
U(rms)=U(p-p)/2/√2
volt0,64
Hydrophone
voltagein11
degrees
UHydr=20logU(rms)dB//1V
-3,9
Bearingstb/port)°
-36
Tiltangle
°
0
Depthbelowkeel
meter
13
General
information
Watertemperature
°C
16
Table8Sourcelevel(SL)forOmniand11degrees
SL=UHydr-M+20logR
ValueUnitExample
UHydrophone
dB//1V
-9.9
Mtotal
dB//1V/µPa
-209.6
20logRdB17.5
Omni
SLOMNIdB//µPa
217.2
UHydrophone
dB//1V
-3.9
Mtotal
dB//1V/µPa
-209.6
20logRdB17.5
11degrees
SLOMNIdB//µPa
223.2
144
307531/C

Table of Contents

Related product manuals