SimradSX90
Mainorbilgekeels
Zincanodes
Coolingelementsprotrudingfromthehull
Equipmentsuchassonartransducersandpilottubes
Seachests
Overboarddischarges
Dentsinthehull
Allappendagestothehull,indentationsandpipein/outletsare
potentialsourcesofunderwaternoise.Theymayactasresonant
cavitiesamplifyingnoiseatcertainfrequencies,createcavitation
orturbulence.Transducersshouldnotbelocatedinthevicinity
ofsuchobjectsandespeciallynotimmediatelyaftofthem.
Sonarroomrequirements
Itisstronglyrecommendedtouseadedicatedcompartmentto
housethehullunitandthetransceivercabinet.Thesetwounits
mustalsobeinstalledrelativelyclosetoeachotherduetothe
limitedlengthofthetransducercables.Observetheseminimum
sonarroomrequirementstoobtainsuitableworkingconditions
forsonarinstallation,useandmaintenance.
Sizeandaccess
Awelldesignedsonarroomreducestheriskofcorrosionand
simpliesmaintenanceincreasingsystemreliability.
Thesonarroommustbedimensionedtohousealltherelevant
cabinetsthatcomprisetheSX90Fishndingsonar.
ThephysicaldistancebetweentheTransceiverUnitandthe
hullunitislimitedduetothelengthofthetransducercables.
Thesonarroommustnotbeunnecessarilyobstructedby
girders,pipesetc.whichmightcauseinstallationproblemsor
impedemaintenance.
Thesonarroommustbeaccessibleunderallconditionsat
seaorataberth.
Alldoorsorhatchesmustbedesignedsothattheequipment
canberemovedwithoutbeingdisassembled.
Heating
Thesonarroommustbeequippedwithheater,dimensionedto
maintaintheequipmentwithinitsenvironmentaltolerances(at
least1000W),installedclosetothedeck.Heatingisalsoan
effectivemethodforreducinghumidity.