13.5 DEVICE RE-USE AFTER A PERIOD OF IDLENESS
If the device is unused for a long time, abide by the recommendations listed below before a cycle is started.
• Check the filters at the entrance of the water pipes and verify that there is no mud nor rust deposited; in case
sediments are present, let the water from the inlet tap run for some minutes.
• Plug the power (if unplugged).
• Fasten the inlet water pipe and open the tap.
• Verify date and time settings.
• If the detergent system has been flushed, proceed as follows:
• Return the detergent intake nozzles to the jerry cans of the relative products, taking care to put the right
nozzle in each can;
• Run the “Service 1” program (ID_prog 202) twice in succession with no load in the tank.
• Perform a program containing a TD thermodisinfection step, with no load in the device.
The thermodisinfection cycle with the unloaded device is recommended before use in case the device
has been idle for more than 24 hours.
The cycle must be performed with the device empty, with no load in the wash tank (recommended
T_target=93°C).