383
Creating a Cross-Point 
Assign Table
You can create up to 14 other tables (Table1 to Table14) 
as cross-point assign tables.
You can set logical V/K pairs in a cross-point assign 
ta
ble.
Creating Tables 1 to 14
You can assign logical V/K pairs configured in the logical 
V/K pair name table to cross-point button numbers.
1
Open the Home > Setup > Xpt Assign > Table Button 
Assign menu (19102.31).
2
Display the target table to set.
Select a tab to change the table (Table1 to Table14) to 
di
splay.
3
Select the target button number to set.
To select and set multiple button numbers, place a 
ch
eck mark beside the target button numbers to set.
To select and set all button numbers, place a check 
mar
k in the Select All checkbox.
4
Press the [Edit] button.
The [Select Logical V/K Pair] window appears.
5
Set the button for the logical V/K pair to assign to the 
on state.
Select a tab to change the logical V/K pair to display.
6
Press [OK].
To inhibit operation
Select the target button number and set the [Inhibit] 
swi
tch to the on state.
To delete a button number setting
Select the target button number to delete and press the 
[
Delete] button.
The settings for all the button numbers not deleted move 
up
 in sequence.
To insert a button number setting
Select the button number at the insertion position and 
p
ress [Insert].
A button number is inserted and the settings of all other 
bu
ttons are shifted by one.
To return to the initial settings
Press the [Default Recall] button, check the message, then 
press [OK]
.
Setting the Shift Button
Setting the [SHIFT] button operation 
mode
You can set the operation mode of the [SHIFT] button 
assigned to the right edge of the cross-point button row in 
the cross-point control block/AUX bus control block 
(AUX bus operation mode).
You can set it for each cross-point assign table.
The [SHIFT] button operation mode is set by the settings 
of
 the cross-point assign table of the switcher bank, 
regardless of the buses assigned to the cross-point button 
rows.
1
Open the Home > Setup > Xpt Assign > Shift Mode 
menu (19102.41).
2
Select the target table to set.
To select and set multiple tables, place a check mark 
be
side the target tables to set.
To select and set all tables, place a check mark in the 
Sel
ect All checkbox.
3
Press the [Xpt Shift Mode] button and select an 
operation mode from the pull-down list.
Hold: F
unctions as a shift button, and the shifted state 
of a cross-point button is enabled while the button 
is pressed.
Lock: F
unctions as a shift button, and pressing a 
button toggles between the shifted and unshifted 
states of the cross-point.
Off: 
Functions as a cross-point button.
Setting the [SHIFT ALL] button operation 
mode
You can set the operation mode of the [SHIFT ALL] 
button assigned to the cross-point pad/function button 
section of the cross-point control block.
The setting is common to all cross-point assign tables.
1
Open the Home > Setup > Xpt Assign > Shift Mode 
menu (19102.41).
2
Set the operation mode using the [Shift All Hold] 
button.
Note