262
Effect Timeline 
Operations (Menu)
Recalling an Effect Timeline
• The first keyframe is executed when an effect timeline 
is recalled. You can also configure a setting such that 
the first keyframe is not executed.
For details about settings, see “Setting the operation of 
the first keyframe when a register is recalled” 
(page 421).
• You can configure a setting such that the state at that 
p
oint in time is inserted automatically as the first 
keyframe when an empty effect timeline register is 
recalled.
For details about settings, see “Inserting the first 
keyframe automatically when an empty register is 
recalled” (page 420).
• You can configure a setting such that when another 
e
ffect timeline register is recalled while editing an 
effect timeline, the edited effect timeline is saved 
automatically (auto save function).
For details about settings, see “Saving an effect 
timeline automatically” (page 421).
• You can configure a setting such that effect timeline 
ed
it mode ends and operation switches to effect 
timeline recall/store mode when a register is recalled in 
edit mode.
For details about settings, see “Exiting edit mode 
automatically when a register is recalled during 
editing” (page 421).
1
Display the [Effect Timeline Recall/Store] taskbar.
The effect timeline switches to recall/store mode.
2
Press the [Recall/Store] button.
The [Recall/Store Register] window appears.
In the [Effect Timeline Edit] taskbar, press the 
[Re
call/Store] button to display the [Recall/Store 
Register] window.
3
Set the button for the target region to the on state.
You can select multiple regions.
For details about the display in the region display 
sec
tion, see “Region display section” (page 263).
Select a tab to change the region to display.
[ME] tab: S
witcher bank regions
[User] tab: U
ser regions
[DME] tab: DME
 regions
[External Device] tab: E
xternal device regions
The first selected region becomes the reference 
r
egion.
To select all regions configured beforehand
Set the [All Regions] button to the on state.
For details about setting the regions selected 
sim
ultaneously, see “Setting Regions Selected 
Simultaneously” (page 402).
To select DME local or DME global for the target 
regi
on to edit
To select DME local, set the [DME Local] button to 
t
he on state.
To select DME global, set the [DME Global] button 
to
 the on state.
• The region selection is common for effect timelines 
and
 snapshots.
• DME local/DME global selection is enabled only 
when
 editing an effect timeline. When recalling, 
saving, or executing an effect timeline, both DME 
local and DME global become the target.
• The DME local/DME global selections are 
co
mmon for all DME regions.
• The DME local/DME global selections are linked 
to
 the [LOCAL] button/[GLB] button in the device 
control block.
4
Press the [Recall] button.
5
Enter a register number in the numeric keypad area.
For details about selecting a register, see “Selecting 
a register” (page 263).
To add a temporary attribute
Set [Effect Diss] in the numeric keypad area to the on 
stat
e.
6
Press [Enter].
The specified register is recalled.
To undo a register recall
To undo a recall immediately after recalling a register, 
pr
ess the [Undo] button.
To set the duration for an effect dissolve 
te
mporary attribute
You can set the duration for an effect dissolve temporary 
at
tribute for each region.
Select the target region to set, press the [Temp Diss 
Dur
ation] button, and enter a duration (number of frames) 
for the effect dissolve in the numeric keypad area.
Notes
Note
Notes