Chapter 19 Control Panel Setup (Panel)
1177
Setting Button Assignments (Prefs/Utility Menu)
Assigning a Function to the Key 2 Row Cross-Point
Buttons
You can assign a function to the key 2 row cross-point buttons of each of the
M/E-1 to M/E-3, or PGM/PST banks, and use them in the same way as the
buttons in the utility/shotbox control block.
1
In the Prefs/Utility menu, press [Key2/4 Bus Button Assign].
The Key2/4 Bus Button Assign menu appears. The cross-point settings for
the key 2 row appear.
2
Refer to “Assigning a Function to a Memory Recall Button in the Utility/
Shotbox Control Block” (page 1171) to make the assignment. Note,
however, the following differences.
The bank setting of knob 1 is from 1 to 5.
The adjustment range of knob 2 is from 1 to the number of cross-point
buttons.
The character string for a button name is a maximum of four characters.
For details of executing a utility/shotbox function with the key 2 row, see
“Executing Utilities With the Cross-Point Buttons in the Key 2 Row”
(Volume 2) and “Executing a Shotbox Function With the Key 2 Row Cross-
Point Buttons” (Volume 2).

Table of Contents