Chapter 10 Special Functions
495
Multi Program 2
For details of the CCP-6224 2M/E control panel, see page 110, and for the
details of the CCP-6324 3M/E control panel, see page 111.
1
In the Transition Module menu, select the switcher bank.
2
In the <NORM/NORM REV/REV Button Assign> group, press [Main/
Sub].
You can now use the [NORM] button as [MAIN], and the [NORM/REV]
button as [SUB].
To assign to macro buttons in the cross-point control block
For details of the cross-point control block, see page 59.
1
In the Engineering Setup >Panel >Config menu, press [Program Button].
The Program Button menu appears.
2
Press [Xpt Module].
The Xpt Module menu appears.
3
Select the switcher bank, then in the <PRE MCRO/POST MCRO> group,
press [Main Sub].
You can now use the [PRE MCRO] button as [MAIN], and the [POST
MCRO] button as [SUB].
To assign macro operations to different buttons
If in the above operation you assigned a Multi Program 2 function to the macro
buttons, you can assign the PRE MCRO and POST MCRO functions to
different buttons.
For details, see “Assigning Functions to User Preference Buttons” or
“Assigning a Function to a Memory Recall Button in the Utility/Shotbox
Control Block” in Chapter 19 (Volume 3).
Examples of Operations in the Multi Program 2 Mode
(When Sharing a Switcher Bank)
To create video on the M/E or PGM/PST bank assigned to both main and sub
operations, use the following procedure.
1
Press the [MAIN] button, turning it on, and turning off the [SUB] button.

Table of Contents