Chapter 10 Special Functions
502
Multi Program 2
a) Keys 2 to 4 are common to main and sub.
Notes
• Allow a transition to complete before carrying out main and sub delegation
switching.
• The sub background A bus (utility 2 bus) is shared with wipe edge border fill.
Making a change to one affects the other.
• Even if the wipe border width is set to the same numeric value for main and
sub, the same image is not obtained.
• Changing the position of the wipe pattern for sub also changes the pattern
size.
Restrictions on Using Multi Program 2 Mode
• The following functions are not available for sub:
– Data copy and swap
– Default recall (except for parametric recall)
– [TRANS] button function (see page 70) (only available on the
Multifunction Flexi Pad)
– [TRACE] button function (see page 73) (only available on the
Multifunction Flexi Pad)
– [AUTO] button function (see page 107)
• Re-entry is limited to four levels. Re-entry is not possible for main and sub
of the same M/E.
However, this restriction can be removed. For details, see “Enabling re-
entry between the main and sub sides of the same M/E bank” (page 499).
• In the following cases, a transition using the fader lever may not be
performed correctly:
– When the main and sub bus toggle modes are set differently
– For a pattern mix, preset color mix, and so on
• For an Internal bus link, GPI link, or External bus link, the “Utility 2” bus
cannot be selected.
• Screen aspect, show key, and [MCRO ATTCH ENBL] button settings are
common to main and sub.
Snapshots Cross-point
hold
Utility 2 cannot be set Utility 3 is added. BKGD
A/B and Key1 cannot be
set.
Control from an editor Same as standard mode Cannot be used
Operation setting for
switcher GPI inputs and
outputs
Same as standard mode Cannot be used
Item Main Sub