Chapter 21  DME Setup (DME)
1254
Settings Relating to Signal Inputs (Input Menu)
Settings Relating to Signal Inputs (Input 
Menu)
To make settings relating to DME input signals, display the DME >Input 
menu.
To display the Input menu
In the Engineering Setup menu, select VF4 ‘DME’ and HF1 ‘Input.’
The status area shows the initial crop information and the DME system phase.
The following functions are available here.
• Initial Crop: Make the initial crop setting.
• Matte Illeg. Color Limit: Switch the illegal limiter for the signal generated 
by the DME internal matte generator on or off.
• System Phase: Adjust the operation timing of the whole system with respect 
to the reference signal.
• TBC Center: Set the TBC window center position.
In the following description, the settings for DME1 are given by way of 
example, but the settings for DME2 are carried out in a similar way.
Setting the Initial Crop
1
In the DME1 <Aspect> group of the DME >Input menu, select the screen 
aspect ratio (16:9 or 4:3).
2
In the DME1 <Crop> group, press [Initial Crop] and adjust the following 
parameters.
• If you selected 4:3 in step 1
Knob Parameter Adjustment Setting values
1 Top Position of top side –3.00 to +3.00
2 Left Position of left side –4.00 to +4.00
3 Right Position of right side –4.00 to +4.00
4 Bottom Position of bottom side –3.00 to +3.00