Chapter 19 Control Panel Setup (Panel)
1182
Interfacing With External Devices (Device Interface Menu)
Turn the knob.
3
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): The trigger causes the relay contacts to be open-
circuit or drives the output high, and holds this state for the
specified pulse width.
(Falling Edge): The trigger causes the relay contacts to be shorted
or drives the output low, and holds this state for the specified
pulse width.
(Any Edge): Each time the trigger occurs, the relay contacts are
alternately closed or opened, or the output is switched between
high and low.
Status: Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation: The trigger has no effect on the relay state or output level.
4
Turning the knobs, select the pulse width and timing to be set.
a) 1: Field 1, 2: Field 2, 3: Any
When “ ” is selected as the trigger polarity, there is no Pulse Width
setting. When “Status” is selected, there is no Pulse Width or Timing
setting.
5
In the <Source> group, select the action block.
M/E-1 to M/E-3 and P/P: Set an action for the M/E or PGM/PST bank.
Common: Set an action for error status.
6
Using any of the following methods, select the action to be set.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knobs.
Knob Parameter Adjustment Setting values
1 Port Port selection 1 to 8
Knob Parameter Adjustment Setting values
3 Pulse Width Pulse width 1 to 60 (fields)
4 Timing Output timing
1 to 3
a)
Knob Parameter Adjustment Setting values
2 Action Action selection
1 and upwards
a)
5 Reg No Register number
1 to 4
b)