Chapter 20 Switcher Setup (Switcher)
1223
Signal Output Settings (Output Menu)
2
Press [V Blank Mask].
3
Adjust the parameter.
a) Depending on the signal format, the adjustment range varies as follows.
480i: 10 to 19
576i: 6 to 22
1080i/1080PsF: 7 to 20
720P: 7 to 25
To return the values to their defaults, press [Default].
4
To enable the through mode, press [Through Mode], setting it to Enable.
The through mode can be applied to the following outputs.
Aux 1 to 48 outputs
Program outputs of the M/E and PGM/PST rows
Clean outputs of the M/E and PGM/PST rows
Making safe title settings
Notes
“Grid” in the following procedure is supported on the MVS-8000G only.
1
In the Switcher >Output menu, press [Safe Title].
The Safe Title menu appears.
The status area shows the output ports and the assigned signals, with the
box 1, box 2, cross, and grid states.
2
To enable the safe title on/off setting made in the Misc menu, press [Safe
Title], turning it on.
3
Carry out either of the following operations.
To display a box: Press [Box1] or [Box2], turning it on.
In this case, carry out the following steps 4 and 5.
To display a cross: Press [Cross], turning it on.
To display a grid: Press [Grid], turning it on (when using the MVS-
8000G).
In this case, carry out the following steps 4 and 5.
Knob Parameter Adjustment Setting values
2 Mask End Final value for vertical blanking
interval
See note a) below