Chapter 10 Special Functions
510
Dual Link Support
This assigns the signal.
Restrictions when using a dual link
When using a dual link, the switcher and DME resources are linked in duplex
(link A and link B), resulting in the following restrictions.
a) When the simple P/P software is not installed
b) When the switcher is a 2M/E system only
Restrictions Details
Functions that cannot be
used in the system
Functions of the following items in the Engineering
Setup >Switcher >Config menu
Single Simul, Dual Simul
Functions that cannot be
used in the switcher
Primary inputs numbers 41 to 80
Outputs number 25 to 48
Monitor buses 2/4/6/8
M/E-2 bank a)
M/E-3 bank
DME utility 1 and 2 buses
Color background 2
b)
Color corrector 2
Frame memory
Format converter
Functions of the following items in the Engineering
Setup >Switcher >Config menu
Switching Timing, M/E Config excluding Standard, and
Logical M/E Assign
Image extraction from video tape
Functions that cannot be
used on the DME
DME channels 3, 4, 7, and 8
Freeze in film mode
“Freeze Timing” in the following effects
Input Freeze, Trail, Decay, KF Strobe (always set to
Frame)
•Brick
Editor ports 3 and 4 when the editor port operation
mode is set to “Independent.
Other restrictions Auto chroma keying operates on the image of link A.
Tallies are generated for the link A signal.
Key frames are created in units of two frames.
It is not possible to change the interpolation method in
the DME.

Table of Contents