Chapter 12 External Devices
779
Control of VTRs, Extended VTRs, and Disk Recorders
3
Press the [SET DUR] button, and enter “–100” from the numeric keypad
control block.
START TC remains the same, and STOP TC changes.
a)
Example 2
1
Press the [SET DUR] button, and enter “200” from the numeric keypad
control block.
2
Press the [SET STOP TC] button, and enter “01000000” from the numeric
keypad control block.
This automatically sets START TC.
3
Press the [SET STOP TC] button, and without entering anything from the
numeric keypad control block, press [ENTER].
The STOP TC display, and the START TC display automatically
calculated in step 2 disappear, and the setting of the DUR does not change.
a) If after pressing the [SET XX] button you press the [ + / – ] button in the numeric keypad
control block, you can enter offsets from the existing setting values. Each time you press
this button, the sign of the offset cycles through the settings “ ”(absolute value) t “+” t
”... , and the sign appears in the numeric keypad control block display. If there is no
existing setting value, then it is only possible to enter an absolute value, and not an offset
value.
Setting the start point, stop point, and start delay time in a menu
In the Device menu, you can set the start point, stop point, and start delay time.
START TC
STOP TC
(DUR
00:00:00:00
00:00:02:00
0:02:00)
START TC
STOP TC
(DUR
00:00:00:00
00:00:01:00
0:01:00)
START TC
STOP TC
(DUR
--:--:--:--
--:--:--:--
0:02:00)
START TC
STOP TC
(DUR
00:59:58:00
01:00:00:00
0:02:00)
START TC
STOP TC
(DUR
--:--:--:--
--:--:--:--
0:02:00)