Objet1000 Plus User Guide 6 Operating and Maintaining the Objet1000 Plus 3DPrinter
DOC-06810 Rev.B 6-76
Test Name Description Possible Reason for Failure
Interlock Teststheinterlockintheprinter
cover.
Failureofinterlockmechanism.
Faultylatch.
Disconnectedcable.
CabinTemperature Teststhetemperaturelevelinthe
build-trayarea.
Faultytemperaturesensor(OHDB).
HeadEEPROM Teststheread/writecapabilitiesof
theprint-headdrivercards.
Faultyprint-headdrivercard(s).
HeadVoltage Checksthecontrolofvoltages
suppliedtotheprintheads.
Faultyprint-headdrivercard(s).
TrayHeater (Futureimplementation.)
Head/BlockHeaters Teststheheatersintheprintheads
andintheprint-blockbody.
Faultyheatersorthermistors.
UVLamps TestseachUVlampattheHigh
Qualitypowerlevel.
FaultyUVlamp.
FaultyUVpowersupply.
DisconnectedUVcable.
AxesLimit Teststhehardwareandsoftware
limitsofallaxes.
Faultyhardwaresensors.
WrongMax Positionparameter.
ParameterSanity
Check
Comparesthevaluesofallprinter
parameters(incfgfiles)tothe
requiredvalues.
Oneormoreoftheprinterparameters
isnotwithintherequiredrange.
DetailsappearintheBITreport.
Vacuum Teststhevacuumlevelintheprint
block.
Faultyvacuumsensor.
Vacuumleakage.
Wrongparameters.
AmbientTemperature (Futureimplementation.)
EvacuationSensor Checkstheflowofexhaustairfrom
theprinter.
Blockedairventorduct.
Faultyventilationfan.
Faultyair-flowsensor.