VAP416 Installation & Operation Manual
TD-1/07-004
23 / 81
Main Function
Second Function
VPC108: 1-8
VPC016: 1-16
VPC116: 1-16
VPC132: 1-32
Zone is open
Number is selected
Power
Power
-
Program
In program mode
-
Bypass
There is bypassed zone
Number 0 (VPC108)
Memory
There is event in the memory
Number 9 (VPC108)
Ready
System is ready to arm
-
Armed
System is armed
-
Trouble
There is a trouble
-
Fire
There is fire alarm
-
4.2.5 Monitoring Event Log
Event log memory is monitored as follows;
CC-DD-HH.MM-A-B
CC: Two digits event code, DD: Day,
HH: Hour, MM: Minute, A,B: A and B parameters
While monitoring event log memory next event can be seen by pressing "▼" button
and previous event can and seen by pressing "▲" button. If number of the event and
then button is pressed, related event can be monitored.
4.2.6 Keypad Customizing
Keypad keeps customizing settings in its own memory. Therefore, any settings made
in a keypad does not effect other keypads.
4.2.6.1 Chime Settings
In order to hear warning sound during any zone(s) is opened or closed you have to
make below settings in the related address:
Operation
VPC108
VPC016-116
VPC132
Chime sound while a zone is
opened
99 01
99 01(1-8 zone)
99 02(9-16 zone)
99 01(1-8 zone)
99 02(9-16 zone)
99 03(17-24 zone)
99 04(25-32 zone)
Chime sound while a zone is
closed
99 02
99 03(1-8 zone)
99 04(9-16 zone)
99 05(1-8 zone)
99 06(9-16 zone)
99 07(17-24 zone)
99 08(25-32 zone)
4.2.6.2. Illumination of Button According to Zone
When any zone is opened buttons can be automatically illuminated. This feature
helps users to find keypad in the dark.