VAP416 Installation & Operation Manual
TD-1/07-004
42 / 81
8.1.7.2. To Set/Make Duress Code
Address 07 31.< MP >
Change for settings:
LED 07 31 <Code> "√"
LCD BASIC SETTINGS→USER CODES→31-USER CODE
<Code> "√"
Entered Value: <code>, 4 digit numbers. If entering "0000", the user will be
cancelled.
Factory default: 0000=User is not defined.
Special Case: Codes can not be seen.
Example: To make the duress code as 5784.
07 31 5 7 8 4
!!! WARNING !!!
The duress code can only be used if and only if the CMS option or any of phone
dialer options is opened. The duress code can only be set on the relevant address by
master program
8.1.7.3. To Set/Make PC Access Code
Address 07 32.< MP >
Change for settings:
LED 07 32 <Code> "√"
LCD BASIC SETTINGS→USER CODES→32-USER CODE
<Code> "√"
Entered Value: <code>, 4 digit numbers. If entering "0000", the user will be
cancelled.
Factory default: 7777.
Special Case: Codes can not be seen.
Example: To make the PC access code as 5784.
07 32 5 7 8 4
Note: PC Access code can only be made/changed on the relevant address of the
master program.
8.2 PANEL SETTINGS
8.2.1. Panel Main Settings
8.2.1.1. Panel Managing
There are the selections which explain what the panel runs. The meaning o these
selections in these addresses are below;
Meaning
Option
ON
OFF
Smart Partition Technology
1
Enable
Disable
Quick arm
2
Enable
Disable
Automatic siren test
3
Enable
Disable
Arm/Disarm from foreign keypad
4
Enable
Disable
Extendable exit delay
5
Enable
Disable
Double hit
6
Enable
Disable
Daylight saving
7
Enable
Disable
Smart Partition Technology
Look at Smart Partition Technology page 30.