VAP416 Installation & Operation Manual
TD-1/07-004
43 / 81
Quick arm
Quick Arm enables arming without user code (User press partition button long
that he/she wants to arm).
Automatic siren test
If Automatic siren test is enabled, siren alarms for 2 seconds.
Arm/Disarm from foreign keypad
If Arm/Disarm from foreign Keypad is enabled, users arm/disarm his/her partitions
without interested in keypad partitions.
Extendable exit delay
Exit delay is extended when enter / exit zone is active if Extendable Exit Delay
feature is enabled.
Double hit
If Double Hit feature is enabled, two alarms from the same zone within cross zone
timer duration will cause panel to go into alarm. Double Hit feature is affects only
zones selected as Cross Zone.
Daylight saving
If Daylight Saving feature is enabled, panel automatically adjusts system time for
daylight saving changes. Daylight Saving feature is developed for the European
Standards.
Address 10 01.< IP >
Display for settings:
LED 10 01 (wait)
LCD PANEL SETTINGS→GENERAL SETTINGS→PANEL OPTIONS (wait)
Change for settings:
LED 10 01 <Value> "√"
LCD PANEL SETTINGS→GENERAL SETTINGS→PANEL OPTIONS
<Value> "√"
Shown/Entered value: <Value>, 1...7 multi selection from the table.
Factory default: 2,5,7 is enabled
Example: To Enable Automatic Siren test do. (3 option)
10 01 3 (turn on) √
8.2.1.2. Output Types
PGM1, PGM2, PGM3, SRN output types(NC/NO) are configured in this address.
Meaning of options is in the following;
1.Option=SRN-Siren, 2.Option=PGM1, 3.Option=PGM2, 4.Option=PGM3.
Address 10 02.< IP >
Display for settings:
LED 10 02 (wait)
LCD PANEL SETTINGS→GENERAL SETTINGS→OUTPUT POLAR (wait)
Change for settings:
LED 10 02 <Value> "√"
LCD PANEL SETTINGS→GENERAL SETTINGS→OUTPUT POLAR
<Value> "√"
Shown/Entered value: <Value>, 1,2,3,4 multi selection from above list
Factory default: All outputs are NO
Example: To set output type as default value
10 02 1 (turn off) 2 (turn off) 3 (turn off) 4 (turn off)